R-454B pressure-temperature chart

R-454B pressure-temperature chart with saturation pressure from -40°F to 140°F, generated from CoolProp; bubble and dew columns are shown where applicable.

Refrigerant R-454BBubble/dew pressure37 rows

What this refrigerant PT chart answers

R-454B is an A2L zeotropic blend intended for newer low-GWP residential air-conditioning equipment.

This page is maintained by the HVAC Calculator Pro Editorial Team. We publish the inputs, calculation basis and limitations so a technician can reproduce the screening result and decide what must be checked in the field. It is a reference aid, not a substitute for the governing code, a licensed designer or the equipment manufacturer's instructions.

Saturation pressure table

gauge pressure · sea-level reference
R-454B saturation pressure
TemperatureEquivalentBubble PSIGDew PSIG
-40 °F-40.0 °C9.8 PSIG8.5 PSIG
-35 °F-37.2 °C13.0 PSIG11.5 PSIG
-30 °F-34.4 °C16.6 PSIG14.9 PSIG
-25 °F-31.7 °C20.5 PSIG18.6 PSIG
-20 °F-28.9 °C24.7 PSIG22.7 PSIG
-15 °F-26.1 °C29.4 PSIG27.1 PSIG
-10 °F-23.3 °C34.5 PSIG32.0 PSIG
-5 °F-20.6 °C40.0 PSIG37.2 PSIG
0 °F-17.8 °C45.9 PSIG42.9 PSIG
5 °F-15.0 °C52.4 PSIG49.1 PSIG
10 °F-12.2 °C59.3 PSIG55.7 PSIG
15 °F-9.4 °C66.8 PSIG62.9 PSIG
20 °F-6.7 °C74.8 PSIG70.6 PSIG
25 °F-3.9 °C83.5 PSIG78.9 PSIG
30 °F-1.1 °C92.7 PSIG87.8 PSIG
35 °F1.7 °C102.6 PSIG97.3 PSIG
40 °F4.4 °C113.2 PSIG107.5 PSIG
45 °F7.2 °C124.5 PSIG118.3 PSIG
50 °F10.0 °C136.4 PSIG129.9 PSIG
55 °F12.8 °C149.2 PSIG142.2 PSIG
60 °F15.6 °C162.7 PSIG155.3 PSIG
65 °F18.3 °C177.1 PSIG169.2 PSIG
70 °F21.1 °C192.3 PSIG183.9 PSIG
75 °F23.9 °C208.4 PSIG199.5 PSIG
80 °F26.7 °C225.4 PSIG216.0 PSIG
85 °F29.4 °C243.4 PSIG233.5 PSIG
90 °F32.2 °C262.3 PSIG251.9 PSIG
95 °F35.0 °C282.3 PSIG271.4 PSIG
100 °F37.8 °C303.3 PSIG291.9 PSIG
105 °F40.6 °C325.4 PSIG313.5 PSIG
110 °F43.3 °C348.6 PSIG336.3 PSIG
115 °F46.1 °C373.0 PSIG360.3 PSIG
120 °F48.9 °C398.6 PSIG385.5 PSIG
125 °F51.7 °C425.5 PSIG412.1 PSIG
130 °F54.4 °C453.6 PSIG440.0 PSIG
135 °F57.2 °C469.3 PSIG
140 °F60.0 °C514.1 PSIG500.2 PSIG

Unavailable table rows

CoolProp did not return a stable bubble-point value for 135 °F. The dash is intentional: do not interpolate it or treat it as zero. Use the equipment manufacturer chart or a validated property source for that temperature.

How to use this R-454B pressure-temperature chart

  1. Identify the refrigerant and confirm the unit's design data plate.
  2. Measure line temperature at the same stable operating point as the gauge pressure.
  3. Use the chart to translate saturation temperature and then apply the manufacturer's superheat or subcooling procedure.

Worked example: At 70°F, compare the gauge reading only after confirming whether the service procedure calls for dew or bubble temperature. This page uses a published 68.9% R-32 / 31.1% R-1234yf mass basis converted to CoolProp molar fractions; verify the blend and dew/bubble convention in the equipment manual.

Record the result with the project address, equipment model, code edition and assumptions. That audit trail is more useful than copying a single number without its conditions.

Continue with the right tool

What is specific to R-454B

Blend composition, glide and A2L safety requirements make a generic single pressure value especially risky for charging decisions.

Safety and climate profile: Safety classification A2L; approximate 100-year GWP 466; zeotropic blend with glide and a published R-32/R-1234yf composition basis.

PSIG is gauge pressure. Absolute pressure adds local atmospheric pressure, so a gauge reading cannot be compared directly with an absolute-pressure chart without conversion.

For the governing safety and refrigerant-transition context, consult the U.S. EPA refrigerant guidance and the equipment manufacturer documentation.

Use boundary: This table does not model line pressure drop, superheat, subcooling, altitude correction or field safety controls. Confirm the correct blend basis and dew/bubble convention before using it.

Data sourceCoolProp 8.0.0 fluid properties (https://coolprop.org/); R-454B uses the published 68.9% R-32 / 31.1% R-1234yf mass blend converted to CoolProp molar fractions.
Review statusScreening reference · not approved for final design
Last verified2026-09-02 · regenerate when the source or code edition changes

Common questions

Can I use the R-454B pressure alone to charge a system?

No. Pressure must be interpreted with line temperature, airflow, operating mode and the manufacturer's charging method.

Why does this R-454B page say bubble point?

Bubble point is the saturated-liquid reference used by this generated table. Zeotropic blends may also require a dew-point reference, so the service procedure controls.